The DrägerSensor CatEx SR (Shock Resistant) is used for detecting combustible gases and vapors, as well as all hydrocarbons (from methane to nonane).

  • High long-term stability
  • Especially insensitive to shock loads
  • Low resistance to sensor poisons such as hydrogen sulfide and siloxanes
  • Measurement range:
    • 0 to 100 % LEL
    • 0 to 5 vol.-% CH4 (methane)
  • Detection limit: 2 % LEL (when calibrated with methane)
  • Resolution:
    • 1.0 % LEL for the measurement range 0 to 100 % LEL,
    • 0.05 vol.-% for the measurement range 0 to 5 vol.-% CH4 (methane)

 

Rental Advanced: Yes
Rental item or Consumable?: Rental items
Sensor Type: CatEx
Sensors: Ex (UEG z.B. CH4)