Skip to main content Skip to search Skip to main navigation

The Multi Gas Detector X-am 5000 Complete Package Ex (catalytic) and O2 enables the measurement of combustible gases and vapors, as well as oxygen.

  • Gas detection device Dräger X-am® 5000 is equipped with an Ex (catalytic) and O2 sensor
  • Detection of hazardous substances in ambient air is possible even at low concentrations
  • Alarm thresholds & measuring gas:
    • Catalytic Ex sensor: Measuring gas = Methane; A1 = 20% LEL, A2 = 40% LEL
    • O2 Sensor - A1/A2 alarm thresholds:
      • Upper alarm thresholds: A1 23 vol.- %; A2 24 vol.-%
      • Lower alarm thresholds: A1 19 vol.-%; A2 17 vol.-%
  • Complete package includes:
  • SRM04207: Dräger X-am® 5000
  • SRM03693: Charging module Dräger X-am 1/2/5x00
  • SRM06539: Plug-in power supply Dräger 12 V/1.2 A (for 1 X-am 7000 or 2 X-am 2/5x00)
  • SRM04311: DrägerSensor CatEx 125 PR
  • SRM04313: DrägerSensor XXS O2

Calibration and Bump Testing Functionality tests (bump tests) and calibration of gas detectors ensure safe operation and functionality of gas monitoring equipment. With our bump test and gas monitor calibration portfolio we enable you to carry out those tests easily and quickly, e.g. due to reduced bump test gas consumption, short testing times, comprehensive documentation and evaluation.

If you wish to configure individual alarm thresholds and/or adjust the Ex sensor, please specify the alarm thresholds and target gas calibration at the end of the order process in the comment field.

Further information about the product can be found on our website. Please follow the Link.

Device type: X-am 5000
Rental Advanced: Yes
Rental item or Consumable?: Rental items
Sensors: Ex (UEG z.B. CH4), O2