Pac 8000 Single Gas Monitor for Carbon Dioxide (CO2)
The Pac 8000 CO2 gas warning device reliably and accurately detects the concentration of carbon dioxide and warns of dangerous gas concentrations.
- Single gas measuring device for personal measurement
- XXS sensor technology with high response speed and membrane filter
- Standard measuring range: 0 - 5 vol.-%, A1/A2 alarm thresholds: 0.5/1 vol-%
- 360° alarm signal, acoustic (90 dB) and optical
- The CO2 gas warning device has a robust, grippy housing for use in extreme conditions
- Large and user-friendly display with bright backlighting
- Storage of concentrations and events with date and time
Carry out the prescribed functional tests before each use with the Dräger test and calibration stations and the associated test gases. The basis for the functional tests are the information sheets T021 / T023 (DGUV Information 213-056 or DGUV Information 213-057). Further information can be found here.
If you wish to have an individual alarm threshold configuration, please specify the alarm thresholds at the end of the order process in the comment field.
Further information about the product can be found on our website. Please follow the link.
Technical Data - Dräger Sensor XXS CO2
| Detection Limit | 0.3 vol.-% |
|---|---|
| Resolution | 0.1 vol.-% |
| Measuring Range | 0 to 5 vol.-% CO2 (carbon dioxide) |
| Response Time | ≤ 30 seconds (t50) |
| Precision Sensitivity | ≤ ± 20 % of the measured value |
| Long-term Drift (at 20 °C) |
|
| Warm-up Time | ≤ 12 hours |
| Ambient Conditions |
|
| Temperature Influence |
|
| Humidity Influence |
|
| Test Gas | 1 to 4 vol.-% CO2 |
Relevant Cross-Sensitivities - Dräger Sensor XXS CO2
The values given in the table are guidelines and apply to new sensors. The specified values may vary by ±30%. The sensor may also be sensitive to other gases (data available on request from Dräger). Gas mixtures can be displayed as a total. Gases with negative sensitivity can offset a positive CO2 reading. It should be checked whether gas mixtures are present.
| Gas/Vapor | Concentration | Display in ppm CO2 |
|---|---|---|
| Ammonia (NH3) | 50 ppm | no influence |
| Chlorine (Cl2) | 10 ppm | no influence |
| Hydrochloric Acid (HCl) | 20 ppm | no influence |
| Hydrogen Cyanide (HCN) | 60 ppm | no influence |
| Ethanol (C2H5OH) | 250 ppm | no influence |
| Ethylene (C2H2) | 100 ppm | no influence |
| Isobutene ((CH3)2CCH2) | 100 ppm | no influence |
| Carbon Monoxide (CO) | 1000 ppm | no influence |
| Methane (CH4) | 0.9 vol.-% | no influence |
| Ozone (O3) | 1.5 ppm | no influence |
| Phosphine (PH3) | 5 ppm | no influence |
| Sulfur Dioxide (SO2) | 20 ppm | no influence |
| Hydrogen Sulfide (H2S) | 20 ppm | no influence |
| Nitrogen Dioxide (NO2) | 20 ppm | no influence |
| Nitric Oxide (NO) | 20 ppm | no influence |
| Hydrogen (H2) | 1.6 vol.-% | no influence |
(-) negative sign of deviation
| Rental Advanced: | Yes |
|---|---|
| Rental item or Consumable?: | Rental items |
| Sensors: | CO2 |