Pac 8000 Single Gas Monitor for Phosgene (COCL2)
The Pac 8000 Phosgene gas detection device reliably and accurately detects the concentration of phosgene and alerts at dangerous gas concentrations.
- Single gas measurement device for personal measurement
- XXS sensor technology with high response speed and membrane filter
- Standard measurement range: 0 - 10 ppm, A1/A2 alarm thresholds: 0.1/0.2 ppm
- 360° alarm signal, acoustic (90 dB) and visual
- The gas detector has a robust, easy-grip housing for use under extreme conditions
- Large and user-friendly display with bright backlight
- Storage of concentrations and events with date and time
Mandatory function tests before each use are conducted with the Dräger test and calibration stations as well as the corresponding test gases. Basis for the function tests are the information sheets T021 / T023 (DGUV Information 213-056 or DGUV Information 213-057). Further information can be found here.
If you wish for an individual alarm threshold configuration, please specify the alarm thresholds in the comment field at the end of the order process.
Further information about the product can be found on our website. Please follow the link.
Technical Data - Dräger Sensor XXS COCl2
| Detection limit | 0.01 ppm |
|---|---|
| Resolution | 0.01 ppm |
| Measurement range | 0 to 10 ppm COCl2 (phosgene) |
| Response time | ≤ 20 seconds (t20) |
| Precision sensitivity | ≤ ± 5 % of the measured value |
| Long-term drift (at 20 °C) |
|
| Warm-up time | ≤ 1 hour |
| Ambient conditions |
|
| Storage | (+4 … +8°C) |
| Temperature influence |
|
| Humidity influence |
|
| Test gas | COCl2 test gas between 3.8 to 9 ppm (not in the Dräger program). |
Relevant Cross Sensitivities - Dräger Sensor XXS COCl2
The values indicated in the table are guidelines and apply to new sensors. The indicated values may vary by ±30%. The sensor may also be sensitive to other gases (data on request from Dräger). Gas mixtures can be displayed as a sum. Gases with negative sensitivity can negate a positive display of COCl2. It should be checked whether gas mixtures are present.
| Gas/Vapor | Concentration | Display in ppm COCl2 |
|---|---|---|
| Ammonia (NH3) | 20 ppm | no influence |
| Chlorine (Cl2) | 0.5 ppm | ≤ 0.2 |
| Hydrogen chloride (HCl) | 0.5 ppm | ≤ 0.7 |
| Hydrogen cyanide (HCN) | 5 ppm | ≤ 6.5 |
| Ethanol (C2H5OH) | 260 ppm | no influence |
| Ethylene (C2H2) | 20 ppm | no influence |
| Hydrogen fluoride (HF) | 0.4 ppm | ≤ 0.1 ppm |
| Isobutene ((CH3)2CCH2) | 100 ppm | no influence |
| Carbon dioxide (CO2) | 1.5 vol.-% | no influence |
| Carbon monoxide (CO) | 1000 ppm | no influence |
| Ozone (O3) | 0.3 ppm | ≤ 0.05 (–) |
| Phosphine (PH3) | 0.5 ppm | ≤ 0.1 ppm |
| Propanol (C3H7OH) | 500 ppm | no influence |
| Sulfur dioxide (SO2) | 2 ppm | no influence |
| Hydrogen sulfide (H2S) | 1 ppm | ≤ 1 |
| Nitrogen dioxide (NO2) | 1 ppm | ≤ 0.1 (–) |
| Nitric oxide (NO) | 30 ppm | no influence |
| Hydrogen (H2) | 8000 ppm | no influence |
| Hydrogen peroxide (H2O2) | 1 ppm | no influence |
(-) negative sign of deviation
| Rental Advanced: | Yes |
|---|---|
| Rental item or Consumable?: | Rental items |
| Sensors: | Phosgen |