Skip to main content Skip to search Skip to main navigation

MicroTubes for carbon monoxide measurement with the X-act 7000

Dräger MicroTubes for carbon monoxide (CO) are short-term measurement tubes for the Dräger X-act 7000 analyser, covering 2 to 1,000 ppm. CO is colourless, odourless and acutely toxic, so it cannot be detected by the senses.

  • Measuring range 2 to 1,000 ppm – matched to the concentrations that matter when you assess carbon monoxide exposure or trace a leak.
  • Read out automatically by the X-act 7000 – the analyser evaluates the tube and shows the concentration directly, so there is no colour scale to judge by eye and no operator interpretation to defend afterwards.
  • Ready to use straight from the box – no calibration, no warm-up time and no sensor to replace; each tube carries its own batch data for the instrument to read.
  • A documented spot measurement in minutes – ideal where a permanently installed monitor would be disproportionate but a defensible reading is still needed.

Measured gas and detection range

  • Carbon monoxide (CO)

Technical data of these MicroTubes

  • Measuring range: 2 to 1,000 ppm
  • Measurement time: approx. 5 to 300 s
  • Standard deviation: ± 25 %
  • Permissible ambient temperature: 10 to 40 °C
  • Permissible humidity: 1 to 40 mg/L

Typical applications for these MicroTubes

  • Boiler houses, foundries, car parks, tunnels and confined space entry.

Instrument compatible with these MicroTubes

  • Dräger X-act 7000