Skip to main content Skip to search Skip to main navigation

The DrägerSensor XXS CO H2-CP measures carbon monoxide in areas where hydrogen is also present

  • None of the usual interference from hydrogen on the CO measurement, as two measuring electrodes are fitted (1. CO and H2; 2. H2) which calculate the true CO content
    • For example, a hydrogen concentration of 1000 ppm (2.5 % LEL) produces a maximum reading of only 15 ppm CO, without triggering the CO alarm
  • High selectivity thanks to a factory-fitted internal filter that removes interfering gases such as alcohol and acidic gases
  • Can be used in Dräger Pac 8500 and Dräger X-am 5000/5600/8000 instruments
  • Expected sensor life of > 3000 years
  • Measuring range
    • 0 to 2000 ppm CO (carbon monoxide)
  • Alarm thresholds
    • A1 = 30 ppm; A2 = 60 ppm

Suitable market segments:
Steel industry, refineries, sewage treatment plants

 

 

Instructions for use

Further information can be found in the instructions for use: Instructions for use for this product

Article type: Rental Items
Rental Advanced: Yes
Sensor Type: XXS
Sensors: CO