The Pac 7000 SO2 is a single-gas monitor for sulfur dioxide. In this configuration, it measures sulfur dioxide precisely and warns of dangerous gas concentrations. The screenshot also shows powerful XXS sensor technology with fast response times, personalized measurement, instant acoustic and visual alarm with vibration, a standard measuring range of 0–100 ppm SO2, IP 68 protection, and a tightly closing crocodile clip.

Further information about our single gas detectors can be found on our website.

Technical Data of the Dräger Sensor XXS SO2

The technical data below provides an overview of the key performance characteristics of the included Dräger sensor.

Detection limit 0.1 ppm
Resolution 0.1 ppm
Measuring range 0 to 100 ppm SO2 (sulfur dioxide)
Response time ≤ 15 seconds (t90)
Precision Sensitivity ≤ ± 2 % of measurement value
Long-term drift, at 20 °C (68 °F)
  • Zero point: ≤ ± 1 ppm/year
  • Sensitivity: ≤ ± 2 % of measurement value/month
Warm-up time ≤ 15 minutes
Environmental conditions
  • Temperature: (-40 to 50) °C (-40 to 122) °F
  • Humidity: (10 to 90) % r. h.
  • Pressure: (700 to 1300) hPa
Temperature influence
  • Zero point: ≤ ± 1 ppm
  • Sensitivity: ≤ ± 5 % of measurement value
Humidity influence
  • Zero point: no influence
  • Sensitivity: ≤ ± 0.1 % of measurement value/% r. h.
Test gas approx. 2 to 90 ppm SO2
Detection limit 0.1 ppm Resolution 0.1 ppm
Measuring range 0 to 100 ppm SO2 (sulfur dioxide) Response time ≤ 15 seconds (t90)
Precision Sensitivity ≤ ± 2 % of measurement value Warm-up time ≤ 15 minutes
Long-term drift, at 20 °C (68 °F)
  • Zero point: ≤ ± 1 ppm/year
  • Sensitivity: ≤ ± 2 % of measurement value/month
Environmental conditions
  • Temperature: (-40 to 50) °C (-40 to 122) °F
  • Humidity: (10 to 90) % r. h.
  • Pressure: (700 to 1300) hPa
Temperature influence
  • Zero point: ≤ ± 1 ppm
  • Sensitivity: ≤ ± 5 % of measurement value
Humidity influence
  • Zero point: no influence
  • Sensitivity: ≤ ± 0.1 % of measurement value/% r. h.
Test gas approx. 2 to 90 ppm SO2

Relevant Cross Sensitivities of the Dräger Sensor XXS SO2

The values given in the table are guidelines and apply to new sensors. The specified values may vary by ±30%. The sensor may also be sensitive to other gases (data on request from Dräger). Gas mixtures can be displayed as a sum. Gases with negative sensitivity can cancel out a positive display. It should be checked whether gas mixtures are present.

Gas/Vapor Chem. Symbol Concentration Display in ppm SO2
Ammonia NH3 50 ppm no influence
Chlorine Cl2 10 ppm ≤ 5 (–)
Hydrogen chloride HCl 20 ppm ≤ 5
Hydrogen cyanide HCN 20 ppm ≤ 10
Ethanol C2H5OH 250 ppm no influence
Ethine C2H2 100 ppm ≤ 140
Isobutene (CH3)2CCH2 100 ppm no influence
Carbon dioxide CO2 1.5 Vol.-% no influence
Carbon monoxide CO 200 ppm no influence
Methane CH4 1 Vol.-% no influence
Ozone O3 0.5 ppm no influence
Phosphine PH3 1 ppm ≤ 6
Hydrogen sulfide H2S 20 ppm ≤ 60
Nitrogen dioxide NO2 20 ppm ≤ 30 (–)
Nitric oxide NO 20 ppm no influence
Hydrogen H2 1000 ppm no influence

Choosing the Right Rental Product for Your Application

Selecting the ideal rental device helps ensure you get the best protection and efficiency for your specific work environment. Consider the types of hazards present, the number of gases to be monitored, and how frequently you’ll need the equipment. Our range of rental products offers flexible solutions - whether you require short-term coverage for a one-off project or long-term use on complex sites. Expert consultation and tailored support are available to help you find the right match for your application.

The following table summarizes the abbreviations, their meanings, and the colour codes used for our Pac gas detection devices.

Abbreviation Meaning (Gas) Color code
H2S Hydrogen sulfide
O2 Oxygen
SO2 Sulfur dioxide No color code
NH3 Ammonia
PH3 Monophosphane
CO H2-CP CO/Hydrogen (combination sensor)
CO Carbon monoxide
CO2 Carbon dioxide
Cl2 Chlorine
HCN Hydrogen cyanide
OV Organic vapors
COCL2 Phosgene

We also offer a range of dual Pac gas detectors. View the full list of Single & Dual Gas Monitors here.

Not sure which device you need yet? Dräger VOICE is here to help.

If you know the hazards you’re facing but are unsure which equipment is right for you, Dräger VOICE can guide you to the most suitable solution. Click hereto explore the tool and find the device that matches your needs.

Application Areas for Portable Gas Detection

Portable gas detection instruments are subject to very diverse requirements. Different application areas require solutions tailored to the measurement task, which also take into account the respective ambient conditions.
It is generally possible to distinguish between the following application areas:

Personal monitoring

Keine unvorhergesehenen Kosten

These devices are designed to warn the wearer about gas risks in the immediate vicinity. For this reason, they are usually worn on work clothing. The basic requirements that these units therefore have to fulfill are wearing comfort, durability, and reliability. Continuously measuring single-gas and multi-gas instruments are suitable for this kind of work.

Area monitoring

Keine unvorhergesehenen Kosten

In contrast to the personal gas detector area monitors will be placed at central or critical locations to monitor workspaces optimally and independently from persons. For this, the basic requirements are robustness, stability and excellent alarm awareness (optical and acoustic) as well as a longest possible battery runtime. Increased security level can be achieved by connecting the area monitors to wireless alarm chains and by transferring the measurement values from instrument to instrument as well as to mobile terminals.

Confined space entry

Keine unvorhergesehenen Kosten

Maintenance and repair work often require people to climb into confined spaces. These areas of work can be especially dangerous because of the lack of space, the lack of ventilation, and the presense or development of hazardous substances. A clearance measurement is required before entry. Multi-gas instruments are used together with corresponding pumps and accessories such as hoses and probes. After a successful measurement where no hazards have been found, the same instruments can be used for continuous personal monitoring while working in the confined space.

Leak detection

Keine unvorhergesehenen Kosten

Leakages can occur wherever gases or liquids are stored or transported. It is important to identify leakages quickly so that the appropriate measures can be taken to avert harm to people, the environment, and the facility. Detection devices combined with corresponding pumps must be able to respond quickly so as to detect small changes in concentration. High levels of reliability are another minimum requirement for these measuring instruments.

Calibration and Bump Testing Functionality tests

Perform the mandatory function tests before each use with the Dräger test and calibration stations and the associated test gases.

If you want an individual alarm threshold configuration, please specify the alarm thresholds in the comment field at the end of the ordering process.

You can also rent bump test equipment for temporary assignments, projects or additional testing tasks. Click here to see our range of products.

Hand touching a black device tester with two gas detectors on a charging station

Associated Rental Items

Discover related equipment and accessories that complement this gas monitor or offer similar functions, helping you find the right tools for your specific safety needs.

Interested in learning more about the rental process, or ready to equip your next project with trusted Dräger technology?

Our team is here to answer your questions, recommend the best solutions, and help make renting safety equipment simple and stress-free.
Reach out today - we’re happy to help you get started.